MTP-200 Series User’s Manual
Shineway Technologies, Inc. - 54 -
➢ Starting point of the link
➢ End point of the link
Important hint: The only way to recover the deleted items is to reanalyze the trace, like
analyze new traces. Please refer to the part “analyze or reanalyze trace”.
Delete event
1. Select the event need to be deleted
2. Click the {Delete} on the right side
3. Press “Yes” when the program hint or press “No” don’t delete event and go back
to main interface.
Fig. 11.7 Delete Event
11.15 Analysis Detecting Threshold Configuration
In order to optimize the event detection, user can set follow analysis detecting threshold:
➢ Change non-reflection threshold (splice loss threshold): It can display or hide
small non reflection event.
➢ Change the reflection threshold (Reflection threshold): It can hide the fake
reflection event caused by noise, turn the harmless reflection event to loss event or
check the event which may cause damage to network and other optical fiber