MTP-200 Series User’s Manual
Shineway Technologies, Inc. - 84 -
5. Be cautious of electric shock and make sure AC power is disconnected with
MTP-200 before cleaning. Always use dry or moist soft cloth to clean the
outside of MTP-200, and never clean the inside
6. Please do not add any accessory to optic instrument or adjust MTP-200 at
discretion.
7. For maintenance, always go to qualified or certified professionals
20.4 Cleaning Tools
1. Optic fiber cleaner (for cleaning of optic connectors)
2. Optic fiber cleaning rod (for cleaning of optic outputs)
3. Optic fiber cleaning tissue (for cleaning optic interfaces)
4. Isopropyl alcohol
5. Cotton ball
6. Paper tissue
7. Cleaning brush
8. Condensed air
20.5 Cleaning Procedure
1. Screw off the cap of flange
2. Clean the laser head carefully
3. Screw on the cap of flange
20.6 Battery Charging Instructions
Typically, MTP-200 Lithium battery supports over 7 hours continuous working.
Charging status is indicated in system main interface and MTP-200 front panel indicator.
1. In system main interface, charging status is displayed in the right upper corner.