MTP-200 Series User’s Manual
Shineway Technologies, Inc. - 75 -
Put protective cap on optical power testing output, and ensure that the tie-in is completely airproof.
“Wavelength”: Support 850, 1300, 1310, 1490, 1550, 1625, 1650nm wavelengths
selectable.
PM100 is only available with the OTDR module built-in PM100. With PM100, OTDR port
will issue a special modulation signal.
Except the specific light port (light port used for online testing), do not connect the optical
fiber which load signal to the OTDR port, any external signal over -30dBm will affect the
OTDR sampling and cause permanent damage to the OTDR.
OTDR built-in source:
1. Clean connector properly.
2. Connect tested fiber to OTDR port.
3. Click {Source/VFL} in OTDR main interface.
4. Select the suitable wavelength.
5. Select the modulation.
6. Press the [Open Source] in the {Source/VFL}.
7. Press the [Close Source] to break off the source.
◆ If there is only one wavelength, the default is to select this wavelength.
◆ Under the modulation for loss measurement, please select the CW.
◆ Under the modulation for fiber identification, please select the 1kHz or 2kHz.
◆ For fiber identification easily, MTP-200 also offers a blink mode. When user select the
blink mode, modulating signal (1kHz or 2kHz) will be emitted in 1s, then the next 1s signal will
be closed, and then will be emitted in next 1s, and so on. User can select 1kHz+Blink or
2kHz+Blink for the Blink Mode.

Table of Contents