Figure 36: Fieldbus module connections
1
CONFIG – Ethernet connection for configuring via PC/notebook
2
BUS OUT – Ethernet connection of the fieldbus
3
BUS IN – Ethernet connection of the fieldbus
4
POWER – Power supply connection
5
DEVICE – Connection for the MLG-2 ProNet
NOTE
Pr
o
tect all unused connections with a plastic cap!
CONFIG connection
The C
ONFIG connection is used to connect a notebook or a PC. You can connect the
MLG-2 via this connection using SOPAS ET.
Table 18: Pin assignment, CONFIG connection of the fieldbus module
Female connector Pin Signal Meaning
43
2 1
1 TX+ Ethernet
2 RX+ Ethernet
3 TX– Ethernet
4 RX– Ethernet
ELECTRICAL INSTALLATION 6
8025190/2020-01-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 WebChecker
43
Subject to change without notice