Prerequisites:
The ML
G-2 was set up for edge measurement.
1. Parameterize the desired function on the “Enhanced Sensing” page in the “Func‐
tional configuration” menu.
The result is on the “Start” and “Enhanced Sensing” pages.
More information:
see "“Functional configuration” menu", page 101
Example
1 2
211
2
Figure 52: Results for “Functional configuration” examples, “Enhanced Sensing” page
1
Result for "F1: Calculation of the width between edges E1 and E10” function
2
Result for "F2: Calculation of the width between the center positions of edges E1 and
E10” func
tion
9.5 Other configurations
You can run the following configurations via SOPAS ET.
For e
xample, the following configurations are possible depending on the MLG-2-variant:
Configure PIN of the M12 male connector on the receiver see "“General settings
area", page 91.
Parameterize analog outputs.
Parameterize switching output and inputs see "“Digital configuration” menu",
page 103.
Configure bus systems.
9 C
OMMISSIONING VIA SOPAS
62
O P E R A T I N G I N S T R U C T I O N S | MLG-2 WebChecker 8025190/2020-01-13 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK MLG-2 WebChecker and is the answer not in the manual?

SICK MLG-2 WebChecker Specifications

General IconGeneral
BrandSICK
ModelMLG-2 WebChecker
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals