EasyManua.ls Logo

SICK MLG-2 WebChecker - T-connector for MLG-2 WebChecker connection

SICK MLG-2 WebChecker
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 22: Pin assignment, sender connection
Male connector Pin Signal Meaning Color
12
3 4
5
1 L+ 24 V supply voltage Brown
2 Sync_A Synchronization White
3 M GND supply voltage Blue
4 Test_In Test input Black
5 Sync_B Synchronization Gray
6.3 T-connector for MLG-2 WebChecker connection
Figure 37: Connection with T-connector
1
Sender
2
Receiver
3
Fieldbus module
4
T-distributor
5
Power supply
6
Fieldbus
A T-connector is available for the MLG-2 WebChecker, which is used to connect the
sender and f
ie
ldbus module to one another, as well as provide facilities for connecting
the voltage supply, the switching output 1, and the test input.
ELECTRICAL INSTALLATION 6
8025190/2020-01-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 WebChecker
45
Subject to change without notice

Table of Contents

Related product manuals