EasyManua.ls Logo

SICK MLG-2 WebChecker - The MLG-2 WebChecker in the Fieldbus Network; The MLG-2 in PROFINET

SICK MLG-2 WebChecker
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 The MLG-2 WebChecker in the fieldbus network
10.1 The MLG-2 in PROFINET
10.1.1 Overview
The MLG-2 ProNet PROFINET supports the following PROFINET features:
•
Cla
s
s B device (PROFINET RT)
•
Cyclic process data: Min. cycle time: 1 ms
•
2 Ethernet ports
•
Net load class III
•
Auto device replacement
•
Media redundancy
•
Topology detection
•
Reduction ratio
•
Acyclic process data, configuration and status: Via NRT data records
•
TCI support
Architecture
PR
OFINET supports a wide variety of topologies such as line, tree, ring, star, and combi‐
nations thereof.
Figure 53: Example of a PROFINET network in a star structure
1
PLC
2
Cyclic data (process data)
3
Acyclic data (service data)
THE MLG-2 WEBCHECKER IN THE FIELDBUS NETWORK 10
8025190/2020-01-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 WebChecker
63
Subject to change without notice

Table of Contents