Ethernet/IP
TM
:
1
2
3
4
5
6
Figure 5: Fieldbus module type label
2
Fieldbus module part number
3
Firmware version
4
Required voltage supply
5
Maximum output current
6
Serial number
3.2 Type code
Example
ML
G-2 with 5 mm beam separation, WebChecker type, measurement field width
750 mm, analog interface, 1 input, 1 digital output as well as 2 analog outputs, no
options, 2.5 m scanning range.
Table 2: Example of an MLG-2 type code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
M L G 0 5 W - 0 1 3 1 B 1 2 5 0 1
Table 3: Meaning of the positions in the type code
Position Meaning
1 … 3 Product family MLG
4 and 5 Beam separation 05 = 5 mm
6 Type W = WebChecker
0 = special t
ype
7 Hyphen
8 … 11 Detection width 0131 = see "Mea
surement field
width", page 14
0000 = special measurement field
width
12 Interfaces, I/O E = EtherCAT
®
H = Et
hernet/IP
TM
N = PROFINET
see "Switching outputs of the MLG-2
WebChecker", page 15
13 Options 1 = none
PRODUCT DESCRIPTION 3
8025190/2020-01-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 WebChecker
13
Subject to change without notice

Table of Contents