8 CLINITEK Status+ Analyzer Operator’s Guide
Introduction
Multistix PRO
®
urinalysis strips are ready to use upon removal from the
bottle and the entire strip is disposable. The strips may be read visually,
requiring no additional laboratory equipment for testing.
The strips can also be read on an instrument, using the
CLINITEK
®
family of Urine Chemistry Analyzers and the appropriate
software; Multistix PRO 11 Reagent Strips are for use on the
CLINITEK 500 and CLINITEK Advantus
®
Analyzers only. The
CLINITEK Status systems, CLINITEK 50 and CLINITEK 100 instruments
automatically identify the strip being tested, using the ID bands near
the handle of the strip. Contact your product representative for further
information.
Multistix PRO urinalysis strips are for in vitro diagnostic use. They have
been determined to be nonhazardous under the guidelines issued by
OSHA in 29 CFR 1910.1200(d).
Getting Started
This section provides information about how to unpack and install your
CLINITEK Status+ analyzer.
Unpacking the ClinitekStatus+ Analyzer
The CLINITEK Status+ analyzer is delivered in 1 carton.
To unpack your CLINITEK Status+ analyzer, perform the following
steps:
1. Carefully remove the contents of the shipping carton.
Note Retain the shipping carton and packing materials, which
offer the best protection against damage if you need to ship the
analyzer.
2. Inspect the carton and contents for visible signs of damage.
If the analyzer appears damaged, immediately file a complaint
with the carrier.
3. Remove each wrapping and verify that you have the following
items (see Figure 1-1):
CLINITEK Status+ analyzer
Power supply adaptor and AC power cord

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CLINITEK Status+ and is the answer not in the manual?

Siemens CLINITEK Status+ Specifications

General IconGeneral
DisplayLCD
Sample TypeUrine
Measurement MethodReflectance photometry
TypeUrinalysis Analyzer
Test TypesUrine Chemistry
ConnectivityRS232 port
Weight5.0 kg
Power Supply100-240 V AC, 50-60 Hz
Data StorageUp to 200 patient results
Test ParametersLeukocytes, Nitrite, Urobilinogen, Protein, pH, Blood, Specific Gravity, Ketone, Bilirubin, Glucose
Test StripsMultistix and other compatible strips