Troubleshooting
13.2 Specifically
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
195
240 Integrator not config-
P002-P017 must be
241 ✓ No PID mA Input PID Process Value
Source (P402) or PID
Setpoint (P414) has
been programmed for a
mA Input, however mA
Input Function (P255)
has not been pro-
242 ✓ No PID mA Output PID System (P400) has
been turned on, but mA
Output (P201) has not
been programmed
243 No batch setpoint relay Batch has been set up,
but no relay has been
configured for a set-
244 ✓ No speed relay Second speed sensor
configured, but no relay
PF Power Failure Displayed at the bottom
right corner of the dis-
play if power is inter-
rupted after the
integrator has been
calibrated.
a)
The codes in this column with checkmarks will produce relay output for a diagnostic alarm.