Recalibration
7.2 Material Tests
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
71
Material Test
Add to Totalizer 0-No 1-Yes
If yes, the weight of the material test will be added to the tota
lizer, if no, material is Material Test
added to test totalizer (4) only. For example, do not add weight of material test to totalizer.
Press the following keys:
Material Test
Press ENTER to start
Press the following key:
Material Test
Press ENTER to start
tonnes
#.### t
The totalizer reading as the material test is run.
Press the following key:
Material Test
ENTER actual amount
964.032 t
tonnes
For example: the weight totalized by the belt scale and BW500 and BW500/L 975.633 kg is the actual
weight of the material test.
Press the following keys in a sequence:
Material Test Deviation
Accept 0-No, 1-Yes
-1.19
The calculated deviation is displayed as a % of the actual weight.