Restoring the default settings using the DIL switch
1.
The power supply is shut down.
2. Select the MRES operating mode by
– Setting mode selector switches S1 to S3 to OFF AND
– Using the service selector switches to ensure that no service functions are selected (S4
to S7 = OFF).
(See figure below.)
6ZLWFKVHWWLQJ 21
6ZLWFKVHWWLQJ 2))
0RGHVZLWFK
6WR6
6HUYLFHVHOHFWRUVZLWFK
6WR6
21
Figure 5-42 MRES switch position
3. Restart the power supply.
The SIMOTION user data is deleted. The default settings are loaded. SIMOTION D410
remains in STOP mode.
4. Change to the required mode by setting the DIL switch.
Note
The default communications parameters are now restored. You must re-configure the
communication parameters of SIMOTION D410.
5.17 System shutdown
All
axes and system components must be in safe state before you shut down the system. You
can set up this safe state by providing a separate motion task, for example.
You can shut down the power supply after the system has reached a standstill state.
Note
You must observe the safety notices for SINAMICS components, which you can find in the
corresponding SINAMICS manuals.
Commissioning (software)
5.17 System shutdown
SIMOTION D410
Commissioning Manual, 04/2014 157