5.6.3 Testing an axis with the axis control panel
Axis control panel
The axis control panel is used exclusively for testing axes.
You can use the axis control panel for the following tasks, for example:
Testing all system components before the axis movement is controlled by a program
Testing as to whether you can move the axis using the axis control panel if a fault is detected
Moving the axes for tuning purposes (controller tuning)
Executing active homing
Setting and resetting the axis enable signal
To test the axis that was created
Prerequisites
The following requirements must be fulfilled for testing:
The project has been downloaded to the target system.
SIMOTION SCOUT is in online mode.
The mode selector switch is at STOPU:
Recommendation: Operate the mode selector switch via SIMOTION SCOUT only ("Target
system" > "Control operating mode").
Commissioning (software)
5.6 Creating and testing an axis
SIMOTION D410
118 Commissioning Manual, 04/2014

Table of Contents

Other manuals for Siemens SIMOTION D410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 and is the answer not in the manual?

Siemens SIMOTION D410 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410
CategoryControl Unit
LanguageEnglish

Related product manuals