EasyManuals Logo

Siemens SIMOTION D410 Commissioning Manual

Siemens SIMOTION D410
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
There is no selection option in the "Insert SIMOTION device" dialog box - in special
circumstances
(e.g. for existing systems) PROFINET version V2.1 can also be configured for
V4.1 CPUs. A CPU must be replaced in HW Config for this purpose.
Please note that separate SIMOTION D firmware is available for PROFINET versions V2.1
and V2.2. The required firmware can be found on the SCOUT DVD, as well as at Internet
address (
http://support.automation.siemens.com/WW/view/en/31045047).
Mixed operation of the PROFINET V2.1 and V2.2 synchronization processes is not possible
in a network.
Additional references
For further information on IRT in accordance with PROFINET standard IEC 61158 V2.1 and
V2.2, refer to the
SIMOTION Communication
System Manual.
Result
If you have not yet configured a PG/PC in your project, you can select the interface for the PG/
PC connection now.
4.2.2 Configuring the properties of the PROFINET interface
Procedure
After you have closed the "Insert SIMOTION device" dialog box by pressing "OK", the
"Properties - Ethernet interface" dialog box is opened on a D410 PN.
If you are using the PROFINET interface, set the interface properties in the "Properties -
Ethernet interface" dialog box.
Parameter assignment / addressing
4.2 Creating a project and configuring the communication
SIMOTION D410
Commissioning Manual, 04/2014 55

Table of Contents

Other manuals for Siemens SIMOTION D410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 and is the answer not in the manual?

Siemens SIMOTION D410 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410
CategoryControl Unit
LanguageEnglish

Related product manuals