EasyManuals Logo

Siemens SIMOTION D410 Commissioning Manual

Siemens SIMOTION D410
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Selecting the TP product version
The desired technology package is selected with fine granularity in SIMOTION SCOUT at
"Target device" > "Select technology packages ...".
Figure 6-9 Select Technology Packages
Note
Device diagnostics can provide information on which technology package product version
has been loaded to a CPU.
Loading technology packages to the target device
Technology
packages are only loaded to the target device if no technology package has been
loaded so far or if "Load to file system" is executed.
If a technology package version changes, the technology package must be explicitly reloaded
to the target device. To do this, proceed as follows:
1. Select "Download project to target system" in SIMOTION SCOUT.
2. Under "Additional CPU options", select the "Replace product versions of the technology
packages" option and confirm with "OK".
For further information, please refer to the online help for SIMOTION SCOUT.
Maintenance and service
6.3 Adapting a project (Upgrading the project / Replacing the SIMOTION controller)
SIMOTION D410
Commissioning Manual, 04/2014 183

Table of Contents

Other manuals for Siemens SIMOTION D410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 and is the answer not in the manual?

Siemens SIMOTION D410 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410
CategoryControl Unit
LanguageEnglish

Related product manuals