Recording of interpolation points in the logger
Interpolation points are recorded on every change.
Changes can occur during operation in semi-automatic mode (SAM), for example when:
The override changes
The prelimit switch responds
A new target is specified or the offset is changed (S_OFFS)
Recording of variables
The following variables are recorded by the logger:
Control word trolley
Status word 1 trolley
Control word hoist
Status word 1 hoist
Control word 1 Common
Control word 2 Common
Error double word FAULT1
Status word 1 common
Status double word INFO_NO_AUTO_START
Target positions
Interpolation points
Obstacles
Override trolley and hoist
Offset (S_OFFS) for trolley and hoist
Intermediate targets S_Max during movement along the trajectory
Factor for reduction of sway control
Immersion point
Number of the selected lane
Switchover in the SIMOTION D4x5-2 DP/PN: STOP → RUN
SIMOCRANE CeCOMM commissioning and diagnostic program
8.9 Logger
SC integrated STS, GSU
312 Operating Instructions, 07/2019, A5E48271265B AA