11.1 Overview of the parameter list
The parameters for configuring the sway control system are grouped as follows:
Trolley parameters P0 to P39
Hoist parameters P40 to P79
Sway control parameters P80 to P99
General parameters P100 to P119
Camera/reflector parameters P120 to P139
Travel behavior parameters P140 to P159
Controlled variable parameters P160 to P179
TLS parameters P240 to P336
Option parameters
Parameters, in which one or more options can be selected, are identified by a "#" in front of the
character string. Selected options are specified with the corresponding digit; options that are
not selected, with a dot "."
Examples of parameter P152 (conventional/time-optimized control, trolley):
#.... None of the four options has been selected.
#.23. Options 2 and 3 of four options have been selected.
#123. Options 1, 2 and 3 of four options have been selected.
Note
Only the default values are specified for the parameters with selection options, but not the
minimum and maximum.
11.2 Trolley
P0 Maximum output velocity, trolley
This value corresponds to the maximum attainable velocity (V_POS).
Default: 3500 [mm/s] min: 10 [mm/s] max: 7000 [mm/s]
Access code: 0 Display: Always
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA 393