Default: 0
Access code: 0
P321 Cylinder control disabled
Software is used solely for skew-damping purposes. The cylinder control functions are
deactivated.
0: Cylinder control on
1: Cylinder control off
Default: 0
Access code: 0
P322 Position conversion factor for skew drive
The actual position of the skew axis is calculated as follows:
s_act_SkA = P322 · RPOS_SKEWAXIS + P323
Default: 1 [mm] min: -100000 [mm] max: 100000 [mm]
Access code: 0
P323 Position conversion offset for skew drive (spindle)
The actual position of the skew axis is calculated as follows:
s_act_SkA = P322 · RPOS_SKEWAXIS + P323
Default: 0 [mm] min: -100000 [mm] max: 100000 [mm]
Access code: 0
P324 Maximum position for skew drive (spindle)
Maximum position for skew drive (spindle)
Default: 240 [mm] min: 0 [mm] max: 10000 [mm]
Access code: 0
P325 Max. velocity of skew drive (spindle)
Maximum velocity for the skew drive.
The output velocity is limited to this maximum value.
Default: 50 [mm/s] min: 0 [mm/s] max: 10000 [mm/s]
Access code: 0