EasyManua.ls Logo

Siemens VDO DTCO 1381 - Page 257

Siemens VDO DTCO 1381
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service only
Events and faults 13.4 Messages and troubleshooting measures
Edition 07/2007 Technical Description DTCO 1381 13 - 25
TD00.1381.00 132 102
Yo QSJOUFSáGBVMU  4000000700 Printer fault.
Possible causes
The printer’s supply voltage lies outside of the specified
range or has failed.
The temperature of the print head is outside the spec-
ified range or monitoring supplies values which are not
plausible.
Fault on the temperature sensor of the print head.
Measures
Interrupt continuous voltage (perform restart).
After a long printout, the print head temperature is too
high; wait to cool.
If the error message continues to appear despite these
measures and multiple acknowledgements, replace the
DTCO 1381.
1)
2)
Yl EJTQMBZáGBVMU  4000001030 Display fault (sometimes no display).
Possible causes
Data transfer to display controller faulty.
Display defective.
Measures
If the error message appears repetitively, replace the
DTCO 1381.
1)
2)
Ym EPXOMPBEáGBVMU  --- A communication fault has appeared while downloading
card or memory data.
Measures
Repeat download process.
Check connection cable to download station and plug
(poor connection, loose contact, pin assignment).
Check download interface on the DTCO 1381.
Check download station.
Replace any defective components.
2)
Yp TFOTPSáGBVMU  8000002508 Internal sensor fault; the KITAS 2171 motion sensor
announces an internal fault after a self-test.
Measures
Check KITAS 2171.
Replace KITAS 2171 if necessary.
2)
DTCO 1381 display
Picto. AP Error text MC Error code Meaning, cause and measures
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.

Table of Contents

Related product manuals