14.4 Explanation of printout examples Appendix
14 - 22
© Siemens VDO Automotive AG Edition 07/2007
TD00.1381.00 132 102
14.4 Explanation of printout examples
14.4.1 Specification of the data blocks
General Information • Every printout consists of a string of different data blocks that
are identified by block identifiers (1).
• A data block contains one or several data records that are iden-
tified by means of a data set identifier (2).
• A data record will not be printed immediately after a block iden-
tifier!
Explanation
r
jjá
I
ej%
fj'
jjá
I
1
2
Pos. / block Data block specification / explanation
Date and time of the printout in UTC time
Type of printout
Ijo = Daily printout, driver card activities
Yjo = Events and faults from the driver card
Iro = Daily printout, driver activities from DTCO 1381
Yro = Events and faults from DTCO
wwo = Overspeeding instances*
gko = Technical data of the DTCO 1381
Wo = Daily printout speed profiles
Oo = Daily printout rpm profiles
* When "overspeeding instances" is printed, the value set in the speed limiter will also be
printed.
Information about Cardholder (only when tachograph card is inserted)
f = Controller
d = Driver
e = Company
g = Workshop / inspection station
•Last name
•First name
• Card identification
Note
If a tachograph card is not associated with a person, the name of the control body, the
company, or the workshop will be printed instead of the person’s name.
1
2
3