Service only
Events and faults 13.4 Messages and troubleshooting measures
Edition 07/2007 Technical Description DTCO 1381 13 - 33
TD00.1381.00 132 102
v $ TFDVSJUZáCSFBDI  8000002452 Error during authentication of the motion sensor during
operation or error during the pairing procedure.
Possible causes
Error during authentication of the motion sensor during
operation
Multiple coupling with the KITAS 2171.
After three pairing processes, this function will be
blocked for security reasons. The workshop card must
then be withdrawn and re-inserted; i.e., the workshop
card must be re-authenticated.
Measures
As necessary, eject the workshop card and re-insert;
repeat coupling.
Check KITAS 2171 sensor cable.
Check KITAS 2171.
Check DTCO 1381 (input B4).
Use a test device to pair the KITAS 2171 with the
DTCO 1381.
Replace any defective components.
1)
2)
v % TFDVSJUZáCSFBDI  8000002452 Unknown serial number; Error during comparison of the
serial numbers of the motion sensor.
Measures
Check sealing of the KITAS 2171 to the transmission.
Check KITAS 2171.
Check DTCO 1381.
Use a test device to pair the KITAS 2171 with the
DTCO 1381.
Replace any defective components.
1)
2)
v & TFDVSJUZáCSFBDI  00000005B1 Error in data memory. Due to an error in the data memory of
the DTCO 1381, data security is no longer ensured.
Measures
Check DTCO 1381.
If the error message appears repetitively, replace the
DTCO 1381.
2)
v ' TFDVSJUZáCSFBDI  00000005B1 The DTCO 1381 housing was or is opened.
Measures
Check sealing (housing) of the DTCO 1381.
Check DTCO 1381.
If the error message appears repetitively, replace the
DTCO 1381.
2)
DTCO 1381 display
Picto. AP Error text MC Error code Meaning, cause and measures
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.