Chapter 9 Storage Devices 9-7
FIGURE 9-5 Jumper Settings for Conner 535-Mbyte Drive
TABLE 9-1 describes the 535-megabyte Conner drive’s factory jumper settings.
TABLE 9-1 535-Mbyte Conner Drive Configuration Jumpers
Pin Pair Description Factory Set
E1 SCSI ID address Yes
E2 SCSI ID address Yes
E3 SCSI ID address No
E5
E4
E3
E2
E1
Power connector
SCSI device
(E1 and E2 jumpered)
address jumpers
SCSI power
(E5 jumpered)
SCSI address 3
terminator
Data connector
SCSI power terminator
(E6 not jumpered)
A0 = E1 0, or 1 when jumpered
A1 = E2 2 when jumpered
A2 = E3 4 when jumpered
Serial port jumpers
(not jumpered)