1/10 and 10-Gigabit Layer 2/3 Ethernet Switches User’s Manual
5-80
GARP Timers
Clicking the GARP TIMERS tab brings up the GARP TIMERS CONFIGURATION page
(Figure 5-64), which displays the various parameters for changing Garp times. The
parameters for this page are shown in Table 5-48.
Figure 5-64. Garp Timers Configuration Page
Table 5-48. Garp Timers Configuration Page Parameters
Parameter Description
Port No This parameter displays the Port Number.
Garp Join Time
(msecs)
This parameter configures GARP join time in milli seconds. The value ranges
from 1 to 1073741810. The default value is 200 milli seconds.
Garp Leave Time
(msecs)
This parameter configures GARP leave time in milli seconds. The value ranges
from 1 to 2147483630.The default value is 600 milli seconds.
Garp Leave All Time
(msecs)
This parameter configures GARP leave all time in milli seconds. The value
ranges from 1 to 2147483640.The default value is 10000 milli seconds.