1/10 and 10-Gigabit Layer 2/3 Ethernet Switches User’s Manual
5-20
TACACS+ Servers
Clicking the TACACS+ SERVERS tab brings up the TACACS+ SERVER CONFIGURATION
page (Figure 5-11), which allows you to configure TACACS servers. The parameters for
this page are shown in Table 5-6.
Table 5-5. TACACS+ Global Settings Page Parameters
Parameter Description
Active Server IP
Address
Specifies the IP address of the active TACACS server. This server should have
been already configured in the TACACS+ S
ERVER CONFIGURATION page
(Figure 5-11). The factory default is 0.0.0.0.
Retries
This parameter determines the number of times the switch searches the active
TACACS server from the list of servers maintained. The allowed values are from
1 to 100. The factory default is 2.
Figure 5-11. TACACS+ Server Configuration Page
Table 5-6. TACACS+ Server Configuration Page Parameters
Parameter Description
IP Address This specifies the IP address of the TACACS server. The factory default is blank.
Port
This specifies the TCP port for TACACS protocol. The valid range is from
1 to 65000. The factory default is
blank.
Single Connection
Specify Yes or No for a single TCP connection. If Yes, it establishes only a single
TCP connection with a given TACACS server. The factory default is Yes.