EasyManuals Logo

Svantek SV 971A User Manual

Svantek SV 971A
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
SV 971A User Manual
122
Repetition
Cycles
Number of measurement/integration repetitions
after the <Start> key pressure.
This enables to make a series of measurements
without pressing the <Start> key and save this
series in the results file.
Chapter
4.1
LEQ
Integration
Type of integration of RMS based results (RMS
detector): Linear or Exponential. The IEC 61672-
1:2013 standard requires Linear integration, without
time weighting, however in some countries old
regulation refers to the Exponential RMS integration
with standard time weighting: Fast or Slow.
Chapter
4.1
Linear
Linear type of integration of RMS based results
(RMS detector), without time weighting according to
the IEC 61672-1:2013 standard.
Chapter
4.1
Exponential
Exponential type of integration of RMS based
results (RMS detector), where averaging is a
continuous averaging process that weighs current
and past data differently. The amount of weight
given to past data as compared to current data
depends on the exponential time constant. In
exponential averaging, the averaging process
continues indefinitely.
Chapter
4.1
Day Time
Limits
Definition of the day and night periods required by
local standards: 6–18h and 7–19h. These limits are
used for the calculation of the L(den) function.
Chapter
4.1
LRx Time
Definition of the integration periods for calculating
the LR1 and LR2 results.
Chapter
4.1