System Manual 5. Installation
76.7300FP11/2, Rev A 8/09 Page 2-77
Software Version : FP1.0
Vendor : Tellabs
Product : Tellabs 73xx
Last SW Update : 0-0-0,0:0:0.0,
Last System Backup : 0-0-0,0:0:0.0,
__ 2. Access the Global Configuration mode by entering the following
command:
t7300-tlab7300# configure terminal
__ 3. Enter the following command to configure the System Power Supply
redundancy setting to non-redundant:
t7300-tlab7300(config)# system power-redundancy non-redundant
__ 4. Enter the following command to exit the Global Configuration mode:
t7300-tlab7300(config)# end
__ 5. Enter the following command to display current system status and
verify that the System Power Supply Redundancy setting changed to
Non-Redundant:
t7300-tlab7300# show system information
System response:
System ID : tlab7300
System Contact : Tellabs Technical
Assistance at 1.800.443.5555
System Location : Tellabs Operations, Inc, USA
System Site : TELLABS
System Configuration : 10G-Switch
System Power Supply Redundancy : Non-Redundant
System Switch Redundancy : Non-Redundant
Logging Option : Console Logging
Login Authentication Mode : Local
Config Save Status : Not Initiated
Remote Save Status : Not Initiated
Config Restore Status : Not Initiated
Software Version : FP1.0
Vendor : Tellabs
Product : Tellabs 73xx
Last SW Update : 0-0-0,0:0:0.0,
Last System Backup : 0-0-0,0:0:0.0,
One Power Cable Available
__ 1. To put the system into config mode, enter the following command:
t7300-# configure terminal
__ 2. If a redundant PSU module is installed and not using the UB2 input
(refer to Figure 5.19, page 2-64), you may need to disable alarm
profiles by entering the following command:
t7300-(config)# alarm-profile
__ 3. Enter the following command:
t7300-(config-alarm-profile)# map alarm name tlabEqPowerFeedBNotif severity not-alarmed
__ 4. Enter the following command:
t7300-(config-alarm-profile)# end