System Manual 6. Maintenance
76.7300FP11/2, Rev A 8/09 Page 2-93
__ 6. Log in to the system and verify alarms by performing the following
steps:
__ 6.1 Log in to the Tellabs 7300 NE CLI.
__ 6.2 Display all alarms by entering the following command:
show active-conditions
Note: System response varies based on system configuration and state.
__ 6.3 Confirm that the system does not have alarms that
preclude you from replacing a specific module.
__ 7. Create a database backup. Refer to Back Up the Database to Flash,
page 2-87.
__ 8. When you open or close a module, move the ejector handles
simultaneously, unless otherwise directed.
Note: Some modules may require tools to open and close; each procedure lists
the required tools in the appropriate module replacement section.
Replacing a CMCC Module (Tellabs 7345 Switch only)
6.14 Replace a CMCC module by performing the following steps:
__ 1. Perform the steps in the Module Replacement Pre-Checklist,
page 2-92.
__ 2. Use an antistatic wriststrap connected to the shelf to ensure you are
adequately grounded while installing or servicing the system. Do this
to avoid damaging components sensitive to static electricity. Connect
the antistatic wriststrap to the shelf as shown in Figure 6.1, page 2-94.
__ 3. Ensure the Power/Status LED is not flashing green. If the LED is
flashing, wait for it to stop before continuing.
Warning:
The Tellabs 7345 Switch will be reset if this procedure is not followed.