System Manual 5. Installation
76.7300FP11/2, Rev A 8/09 Page 2-75
Initializing the Tellabs 7300 NE
5.74 Initialize the Tellabs 7300 NE by performing the following steps:
__ 1. Power up Tellabs 7300 NE.
__ 2. Verify the following module LED states:
Tellabs 7345 Switch:
__ 10G Switch module: Active=green, Power=green, Fault=off
__ Fan Tray: Power=green
__ PSU: +12V=green
__ CMCC: Active/Standby=green, Power/Status=green
Tellabs 7325 Switch:
__ Active=green, Power=green, Fault=off
__ PSU: +12V=green
Complete step 3, page 2-75 if you have an Ethernet connection via the
MGT1 port or skip to step 4, page 2-75 if you are connected to the system
via the CT port.
__ 3. Telnet to the default IP address (10.0.0.1) by entering the following
command at the prompt:
Telnet 10.0.0.1
Continue with step 5, page 2-75.
__ 4. Connect to the Command Language Interface (CLI) and verify the user
prompt is seen. Initial bring-up may occur on any of the interfaces
(local serial port, local Ethernet port).
__ 5. Log in to the Tellabs 7300 NE by entering the following commands:
Login: [login_name]
Password: [password]
Where:
login_name = Login name.
password = User password.
__ 6. Verify the software load by entering the following command:
show system information
System response:
System ID : Tellabs
System Contact : Tellabs Technical Assistance at 1.800.443.55
55
System Location : Tellabs Operations, Inc, USA
System Site : TELLABS
System Configuration : 10G-Switch
System Power Supply Redundancy : Redundant
System Switch Redundancy : Non-Redundant
Logging Option : Console Logging
Login Authentication Mode : Remote
Config Save Status : Not Initiated
Remote Save Status : Not Initiated
Config Restore Status : Successful
Software Version : FP1.1