5.3. Setting up alarms
34
Note: If RTKis selected and an AGI-3 or AGI-4 is connected, the
base station settings can be automatically synced with the entered
receiver settings. Select System / GPS / Base Station Sync and
follow the instructions displayed on the wizard.
l VTG legacy mode:Supports VTG data output for NMEA
standards below V4.00. Outputs VTG strings compatible with
NMEA V3 and below.
5.3. Setting up alarms
If no implements have been set up in the system, only General alarms
are available to set up.
To set up general alarms:
1.
Select System / Alarms / General .
The list of general alarms is displayed. All general alarms may be
enabled or disabled by selecting All General Alarms.
Alternatively, each general alarm may be enabled or disabled
independently.
Note that for safety reasons, the Steering Engage/Disengage audible
alarm may not be disabled.
The End of Row alarm requires extra information. This alarm sounds
and displays when the vehicle is approaching the boundary and the
operator should slow down to prepare for manual control.
l First Distance: Distance from the boundary at which the alarm
will first trigger. Distance is measured from the tractor to the
boundary along the wayline (guideline).
l Second Distance: Distance from the boundary at which the
second alarm will trigger, warning the operator to immediately
take control of the vehicle.
l Look Ahead Distance: Sets how many meters in front of the
vehicle that the system looks to respond with actions.
5.3.1. Alarm window description
To acknowledge an alarm, press the center of the alarm window.