ELECTRICAL
8-3536” & 40” Toro GrandStand Service Manual
8
3. Secure the starter positive cable to the LH solenoid
stud with a nut and lock washer. Torque to 35 in-lbs.
(4 Nm) (Fig. 832).
9. Position the battery onto the battery bracket then
secure the red positive cable to the battery positive
terminal using the bolt, washer, and nut (Fig. 834).
Fig. 832 DSCN-2276a
Fig. 834 DSCN-2270a
8. Secure the positive battery cable and the wire
harness red wire eyelet to the solenoid using a nut
and lock washer, torque to 35 in-lbs. (4 Nm), then
position the positive cable terminal cover over the
terminal connection (Fig. 833).
Fig. 833 DSCN-2353a
10. Secure the black ground cable to the battery
negative terminal using the bolt, washer and nut
(Fig. 835).
Fig. 835 DSCN-2265a