HYDRAULIC DRIVE SYSTEM
6-3136” & 40” Toro GrandStand Service Manual
6
Hydraulic Testing
9. Purge the air from the hydraulic system. See
“Bleeding the Hydraulic System” on page 6-35.
8. Fillthereservoirtothe“COLD”uidlevelwiththe
speciedhydraulicuid.SeeyourOperator’sManual
forthespecieduid(Fig.532).
Note: Cleanliness is a key factor in a successful
repair of any hydraulic system. Thoroughly
clean all exposed surfaces prior to any type
of maintenance. Cleaning all parts by using
a solvent wash and air drying is usually
adequate. As with any precision equipment,
all parts must be kept free of foreign material
and chemicals. Protect all exposed sealing
areas and open cavities from damage and
foreign material.
When using a Bi-Directional Flow Test Kit,
determiningdirectionalowisnotnecessary.
Theowmetermaybeconnectedineither
direction into the forward and reverse high
pressure system lines.
Caution:Ensureallttingsandhosesareattached
securely. This test is performed on the
machine’s high pressure system. Failure to
comply could result in serious injury.
1. Place the deck into the transport position.
2. Apply the parking brake.
3. Loosen the four lug nuts (Fig. 533).
Fig. 533 DSCN-2805
Fig. 532 g.71G012685
A. Cap C. Colduidlevel-full
B. Bafe D. Hotuidlevel-full
A
D
C
B