E6582062
11. Table of parameters 11-34
1
9
11
F645 0645
Terminal RR PTC
trip
0: Disabled
1: Enabled
--0Y
[6. 30. 19]
F646 0646
PTC detection
resistance
100 - 9999 3000 Y
F647 0647
Control power
option failure
detection
0: Alarm (no detection
without option)
1: Alarm
2: Trip
- - 0 Y [6. 30. 20]
F648 0648
Number of starting
alarm
0.0 - 999.0
10000
times
999.0 Y [6. 30. 21]
F649 0649 Fallback frequency LL - UL Hz 0.0 Y [6. 30. 16]
F650 0650 Forced run
0: Disabled
1: Enabled
- - 0 Y [6. 31]
F651 0651 Undertorque trip
0: Disabled
1: Enabled
--0Y -
F652 0652
Undertorque
detection level
during power
running
0 - 250 % 0 Y -
F653 0653
Undertorque
detection level
during regen
0 - 250 % 0 Y -
F654 0654
Undertorque
detection time
0.00 - 10.00 s 0.50 Y -
F655 0655
Undertorque
detection hysteresis
0 - 100 % 10 Y -
F656 0656
PTC detection
temperature
0 - 200 °C 90 Y [6. 30. 19]
F657 0657
Overload alarm
level
10 - 100 % 50 Y
[5. 2. 5]
[6. 30. 1]
F658 0658
Number of external
equipment starting
alarm
0.0 - 999.0
10000
times
999.0 Y [6. 30. 21]
F659 0659
Cumulative
overcurrent level
10 - 200 % 100 Y [6. 30. 22]
Title
Communication
No.
Parameter name Adjustment range Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference