8.2.2 Safety monitoring "extraction lid"
Start up the machine again.
Open the cover of the removal chamber by a maximum of 8 mm whilst
the product feed holder is moving:
The feeding action has to be interrupted immediately !
The display will read as follows:
Emergency !
Pass-out chamber
-s3
8.2.3 Safety monitoring "knife box door"
Put the machine into operation again, and open the knife box door by a
maximum of 8 mm during the advance motion of the product feed holder:
The feeding action has to be interrupted immediately !
The display will read as follows:
Emergency !
Knife BOX
-s2
8.2.4 Safety monitoring "infeed cover"
Open the loading door.
Remove the feed cover upwards.
Close the loading door again.
Press the START button.The machine must not start !
The display will read as follows:
Emergency !
Advance covering
-s4
Trial run
02/2005 123842-GB Page 27