8.2. Performance test of the safety switches
If one of the covers is lifted or the knife box door is opened, the machine
is switched off automatically, and the knife must come to a standstill
instantaneously.
If the above action does not take place, the machine must by
no means be put into operation, resp. must not be used any
further !
Note: Defective safety switches may only be replaced by the aftersales
services staff of TREIF or a chartered electrician !
Carry out the performance test of the safety switches as follows:
Set the main switch to »ON«.
Briefly open and close the cover.
Depending on the setting of the ’LID START’ button 2:
–
LID START OFF (lamp off):
Press START button. The machine starts running!
–
LID START ON (lamp on):
The machine starts upon closure of the replenishing cap.
8.2.1 Safety monitoring "replenishing cap"
During the advance motion of the product feed holder, lift the loading door by a
maximum of 8 mm: The feeding action has to be interrupted immediately !
The display will read as follows:
Emergency !
Cutting Chamber
-s1
1 2
Trial run
Page 26 02/2005 123842-GB