6.3. Electrical installation
The machine has to be installed and secured by a chartered electrician
in compliance with the regulations applicable at the location of erection.
Please note the electric circuit diagram in the catalogue of spare parts
in the manual !
Please refer to the identification plate for the power of the back-up
fuse to be provided by the customer.
Check whether the operating voltage mentioned on the identification
plate corresponds to the voltage of your mains supply.
The permissible deviation is 5 % maximum.
It is imperative that the correct phase sequence of the supply voltage
is observed, when the machine is installed !
The machine has been set for “DOCKWISE PHASE SEQUENCE” in the
works of the producer.
If the three-phase socket has an anti-clockwise phase sequence, a
chartered electrician has to change two of the three phases of this
socket.
The installation of the machine has to be effected by means of a
plug-and-socket connection or by means of a lockable mains switch.