Disinfection (after completion of all cleaning measures to be carried out within the room)
Working steps Detergent Process Appliances Notes
Disinfection
small parts
Ecolab:
P3-alcodes
spray low-pressure
cleaning device,
atomiser pistol,
dosage device
Spray small parts
from top to bottom.
Disinfection Ecolab:
1 % *
P3-topax 91
P3-topax 99
spray, lather,
low pressure < 30 bar
depending on the action
range; observe
instructions of Henkel
Company
low-pressure
cleaning device,
atomiser pistol,
dosage device
Spray the machine
from top to bottom.
Please observe the
regulations of the
authorities.
Rinsing potable water low pressure < 30 bar low-pressure
cleaning device,
hose
Observe excerpt
from the Regula-
tions on Meat
Hygiene !
Drying – – – – – – – – – – – –
* = solution in potable water
Excerpt from the Regulations on Meat Hygiene, Encl. 2, II, 4:
Materials, such as detergents and disinfectants, are to be used in such
a way that they do not have a detrimental action on the furnishing
equipment or the working equipment.
They have to be rinsed thoroughly after use.
Check after each cleaning that none of the safety signs are missing or
unreadable.
Cleaning