Connect the cables for Sensor Fail-Open
The Fail-Open Kits minimize the potential risks of in-line Sensor failure on critical network links. You need to purchase these kits
separately. Both copper and optical versions of the kit are available for the one-gigabit ports. The standard Gigabit Fail-Open Kits
and 10 Gigabit Fail-Open Kits are available for the 1 and 10 gigabit ports respectively.
The Monitoring ports of the Sensors can be fail-close; thus, if the Sensor is deployed in-line fail-close, a hardware failure results
in network downtime. Except the built-in RJ-45 ports which come with built-in fail-open functionality, you use either the optional
Trellix's 4-port 1/10 Gigabit Modular Passive Fail-Open kit or external bypass switch provided in an Active Fail-Open Kit for the
Monitoring ports to fail-open.
While the Sensor is operating, the Active Fail-Open kit is in-line and routes all trac directly through the Sensor. When the Sensor
fails, the switch automatically shifts to a bypass state; in-line trac continues to ow through the network link but is no longer
routed through the Sensor. After the Sensor resumes normal operation, the switch returns to the "on" state, once again enabling
in-line monitoring. The port pairs with Active Fail-Open kits resume inline mode after a Sensor resumes normal operation or is in
good health.
G0 supports passive fail-open mode with RJ-11 port control
G0 also supports active fail-open using a Copper and Fiber 1/10 Gigabit Active Fail-Open kit.
G1 and G2 supports built-in fail-open and active fail-open mode for these interface modules:
4-port 10 GigE/1 GigE LR Optical with internal fail-open
4-port 10 GigE/1 GigE SR Optical 50 micron with internal fail-open
4-port 10 GigE/1 GigE SR Optical 62.5 micron with internal fail-open
4-port RJ-45 10 GigE with internal fail-open
6-port RJ-45 1 GigE with internal fail-open
All RJ-45 ports support active fail-open using only a Copper Active Fail-Open kit.
8-port SFP/SFP+ 1/10 Gigabit
The 8-port module supports active fail-open using a Copper and Fiber 1/10 Gigabit Active Fail-Open kit.
G3 supports both internal fail-open and active fail-open mode when connected to an Active Fail-Open (AFO) kit
| NS7500 Sensor3
Trellix Intrusion Prevention System NS-series Sensor Product Guide
151
Note
Note
Note