•
•
6. If the Sensor is not on the same network as the Manager, set the address of the default gateway. Type set sensor gateway
<A.B.C.D> at the prompt.Example:set sensor gateway 192.168.3.68
7. Set the IP address of the Manager server. Type set manager ip <A.B.C.D> at the prompt.Example:set manager ip
192.168.2.8
8. Set the IP address and subnet mask of the Sensor. Type set sensor ip <A.B.C.D> <E.F.G.H> at the prompt.Example:set
sensor ip 192.168.2.12 255.255.255.0
Specify an IP address using four octets separated by periods: X.X.X.X, where X is a number between 0 and 255, followed
by a subnet mask in the same format.
9. If prompted, reboot the Sensor. Type reboot
The Sensor can take up to ve minutes to complete its reboot.
10. Ping the Manager from the Sensor to determine if your conguration settings to this point have successfully established the
Sensor on the network. At the prompt, type the following command:ping <manager IP address>.If the ping is successful,
continue with the following steps. If not, type show to verify your conguration settings and check if the information is
correct.
11. Set the shared secret key value for the Sensor. At the prompt, type the following command:set sensor
sharedsecretkeyThe Sensor then prompts you to enter and, subsequently, conrm the shared secret key value.
This value is used to establish a trust relationship between the Sensor and the Manager. The secret key value can be
between 8 and 25 characters of any ASCII text. The shared key value is case-sensitive. Make sure the value matches the
shared secret key value you provided in the Manager interface while adding the Sensor.
12.
Type show to verify the conguration information. Check that all information is correct.
13.
Type exit to exit the session.
:
Considerations for failover in stacked Sensors
While conguring failover for a stack, you need to take the following factors into consideration:
Both the stacks must be identical to each other with identical connections, network modules, and capacity.
Ensure you have the correct license to congure failover for a stack. The licenses required are as follows:
Trellix Intrusion Prevention System NS-series Sensor Product Guide
| NS9500 Sensors1
68
Note
Note
Note