If you are installing a redundant power supply, you should install it as described in Install a new power supply section. For
true redundant operation with the optional redundant power supply,Trellix recommends that you plug each supply into
a dierent power circuit.
The Sensor has no power switch. The Sensor turns on as soon as one of its power cables is connected to a power
source.Trellix recommends that you use the shutdownCLI command to halt the Sensor before turning it o. For more
information on CLI commands, see the CLI commands section in Trellix Intrusion Prevention System Product Guide
:
Congure the Sensor and Manager for deployment
:
Install the Manager Software
Following steps briey explain the Manager installation:
You must have administrator privileges on the target Windows or Linux server to install the Manager software.
MariaDB is included with the Manager and is installed (embedded) automatically on your target Windows or Linux server
during this process.
Steps:
1. Prepare the system according to the requirements outlined in Trellix Intrusion Prevention System Installation Guide.
2. Close all open applications.
3. Go to Trellix Download Server (https://www.trellix.com/en-us/downloads/my-products.html).
4. Log on using your Grant Number and registered Email Address.
The Find Products page opens.
5. In the Category lter, select Network Security.
6. Click on the Manager version required.
The Available Downloads page opens.
7. In the Type lter, select Installation.
The Manager installation les available for download are listed.
8. Click on the required Manager installation le and the download starts.
Trellix Intrusion Prevention System NS-series Sensor Product Guide