Loading...
9
V01.0| 2017/04

TBPN-L1-FDIO1-2IOL - Standard IO-Link
3 Properties of the IO-Link channels
3.1 General
TBPN-L1-FDIO1-2IOL provides two IO-Link ports at the connectors C6 and C7.
Properties:
2-channel IO-Link master according to specification V1.1
2 universal digital channels, PNP, channel diagnostics, 0,5 A
3.2 Device structure
Fig. 2: Device structure
Meaning
Meaning Power IN
X2 Power OUT
C0 FDI0/1, safety-related input
C1 FDI2/3, safety-related input
C2 FDX4/5, safety-related in-/output
C3 FDX6/7, safety-related in-/output
C4 DXP8/9, standard in-/outputs
(safe shutdown via FSO 0 possible)
C5 DXP10/11, standard in-/outputs
(safe shutdown via FSO 0 possible)
C6 IOL, IO-Link port1
C7 IOL, IO-Link port 2 (safe shutdown via FSO 1 possible)
F-Address Rotary coding switch for address setting for PROFIsafe (F-address set-
ting)
P1 Ethernet 1
P2 Ethernet 2
FE Functional earth