13
V01.0| 2017/04
TBPN-L1-FDIO1-2IOL - Standard IO-Link
3.6 Process data of the IO-Link master channels
3.6.1 Process image TBPN-L1-FDIO1-2IOL
Process input data – complete module
Process output data – complete module
NOTE
Further information about the parts of he process image of TBPN-L1-FDIO1-2IOL which
concern the safe I/O channels and the standard I/O channels can be found in the user man-
uals Part 1, "User manual – TBPN-L1-FDIO1-2IOL – Safety" and Part 2, "User manual –
TBPN-L1-FDIO1-2IOL – Standard-I/Os".
The parts, which are relevant for the IO-Link channels are shown in bold.
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
n to
n + 3
Universal I/O channels
and
IO-Link master channels
n + 4 to n
+ 23
Safe I/O channels
see Part 1,
Process output data - Safe I/O channels
n + 24 to n
+ 87
IO-Link process input data
Diagnostics
n + 88
to
n + 89
Overcurrent diagnostics
n + 90
to
n + 91
DXP diagnostics
n + 92
to n + 95
IO-Link port diagnostics
n + 96
to
n + 159
IO-Link Events
n + 160 to
n + 161
Module status
see Part 1,
Status and control word (page 68)
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
n to
n + 1
Universal I/O channels
and
IO-Link master channels
2 to 9 Safe I/O channels
10 to 73 IO-Link process output data