55
V01.00| 2017/04

TBPN-L1-FDIO1-2IOL- Safe I/O channels
7.12.1 Add emergency shutdown in 64. OSSD
The release circuit remains unchanged as it corresponds to the standard configuration.
Emergency shutdown st SIL3-input FDI0/1, assigned to PROFIsafe bit 1-7.
Fig. 34: 64. OSSD with emergency shutdown
7.12.2 Light grid (AOPD) in 63. OSSD
h Delete the input element "Emergency shutdown".
h Define the input as Safety electronical input
in "Monitor settings o Local I/O".
Fig. 35: Define FDI2/3 as Safety electronical input