Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
12
3.5 Wiring diagrams
3.5.1 IO-Link ports
4
13
2
5
v
1 = V
aux
1
2 = DI/DO
3 = GND (V1)
4 = C/Q
5 = GND (V1)
Pin 2: digital in- or output (DXP)
Pin 4: IO-Link or digital input
1V
AUX1
Class A supply
2 DI/DO Digital input or digital output/Class B supply
3 GND (V1) Ground V1
4 C/Q IO-Link
5 GND (V1) Functional earth
4
13
2
5
v
1 = FSO1
2 = DI/DO
3 = GND (
V1)
4 = C/Q
5 = GND (V1)
Pin 2: digital in- or output (DXP)
Pin 4: IO-Link or digital input
1 FSO 1 Class A supply (safe shutdown possible)
2 DI/DO Digital input or digital output/Class B supply
3 GND (V1) Ground V1
4 C/Q IO-Link
5 GND (V1) Functional earth
ATTENTION!
Wrong supply of IO-Link devices (Class A)
Damage to the electronics
h The IO-Link devices (Class A) must only be sup
plied with the voltage VAUX1 provided
at the supply terminals.
IOL1 at C6
IOL1 at C7