49
V01.00| 2017/04
TBPN-L1-FDIO1-2IOL- Safe I/O channels
h Enter the name of the authorized person who is in charge of the validation and enter a password.
Fig. 28: Configuration release
The configuration log is part of the
safety documentation of the machine.
h Copy the plain text log to a text editor, save,
print and archive it.
or
h Save the configuration log as text file via "Monitor operations o configura
tion log o save as...",
print and archive it.
NOTE
Chapter 5.8 of the software's online help contains a detailed description of the structure
of the configuration log.
Fig. 29: Release the configuration
h Closing the dialog box with "Yes" activates the pro
tective operation of the device (safety moni-
tor). The device is
started.
¬ After the configuration re
lease, the device is in diagnostics mode.
NOTE
The CODE (in this example 3925) serves as CRC which has to be entered in the PROFIsafe
PLC software
Setting the F_parameters (page 64).