Thursday, May 14, 2009
Creating a New System
You can create up to 500 systems.
To create a new system, select the system type from the following items.
P25 Select for P25 Standard Trunk or One-Freq system
MOT Select for any Motorola Type system
EDCS Select for EDACS WIDE/NARROW or EDACS SCAT system
LT Select for an LTR system
Conventional Select for a non-trunked system.
If you select a P25 type, you need to select more system type information from the following:
Standard Trunk Select for a P25 Standard Trunk system
One-Freq Trunk Select for a P25 One-Freq Trunk system
If you select an EDCS type, you need to select more system type information from the following:
WIDE/NARROW Select for an EDACS WIDE/NARROW system
SCAT Select for an EDACS SCAT system
Once you select the system type, the scanner prompts "Confirm?" and "Yes="E" / No="."".
Confi rm?
Yes=E /No= .
Press [E / yes / gps] to confirm, and the system will be created.
Press [. / no / pri] to reject and return to the Menu of Select System.
When the System is created, the scanner assigns a default System name of "System xxx T" to the new
System. (xxx: 1-3 digits sequential number / T: initial of type; P25=P, MOT="M", EDACS="E", LTR="L",
Conventional="C"). Then, the scanner goes go to Edit System Menu.
Note: Once a system has been created, the system type setting cannot be changed.