ToneAAndToneBSettings < UnidenMan4 < TWiki
Tone A and Tone B Settings
You can configure the scanner to search for tones in several different ways, based on the
values you enter for Tone A and Tone B:
Tone A
setting
Positive number Tone B Setting Positive number
Operation Monitor the channel for two-tone pages only. The scanner opens squelch
and displays the tone information when the following occur:
1. The scanner detects a tone that matches the value you set for Tone
A.
2. The tone is at least 250 ms long.
3. Within 500 ms, the scanner detects a second tone that matches the
value set for Tone B.
4. The second tone is at least 100 ms long.
Tone A
setting
Positive number Tone B Setting 0.0 Hz
Operation Monitor the channel for single-tone pages only. The scanner opens
squelch and displays the tone information when the following occur:
1. The scanner detects a tone that matches the value you set for Tone
A.
2. The tone is at least 1.25 seconds long and not more than 3.75
seconds long.
Tone A
setting
0.0 Hz Tone B Setting Positive number
file:///C|/Documents%20and%20Settings/POpitz/My%20...p/CDImage_090515/Manual/ToneAAndToneBSettings.html (1 of 2)5/26/2009 11:16:04 AM