Operation Monitor the channel for group tones only. The scanner opens squelch and
displays the tone information when the following occur:
1. The scanner detects a tone that matches the value you set for Tone
B.
2. The tone is at least 3.75 seconds long.
Tone A
setting
0.0 Hz Tone B Setting 0.0 Hz
Operation Monitor the channel for two-tone pages, single-tone pages, and group
tones. This tone out search mode works as follows:
1. All detected tones are compared to the three criteria listed above.
2. If the tone meets any one of the criteria, the scanner checks to see
if this tone frequency is already saved to a tone out channel with
the same frequency, modulation, and attenuator settings.
3. If the detected tone matches a saved tone, the scanner opens
squelch.
4. If the detected tone does not match any saved tones, the scanner
opens squelch, flashes the tone information on the display, and
asks if you want to save the tone information.
This page applies to the following scanner(s): BCD996XT BCT15X BCD396XT