Set Delay Time
This setting controls how long the scanner stays on frequencies after a transmission ends before resuming
searching.
Turn [Scroll Control] to select the delay time setting from the following list:
-10 sec
-5 sec
-2 sec
0 sec
1 sec
2 sec
5 sec
10 sec
30 sec
Then press [E / yes / gps] to accept and return to the previous menu.
Set Modulation
You can select the modulation from the following settings.
Auto The scanner uses the modulation normal for the frequency’s band. (See: Band Defaults)
AM The scanner uses AM demodulation.
NFM The scanner uses Narrowband FM demodulation.
FM The scanner uses FM demodulation.
WFM The scanner uses Wideband FM demodulation.
FMB The scanner uses FM Broadcast demodulation.
Press [E / yes / gps] to accept the entry and return to the previous menu.
Set Attenuator
You can select to attenuate RF reception on all frequencies in the search range.
On The frequencies are attenuated.
Off The frequencies are not attenuated.
Press [E / yes / gps] to accept the entry and return to the previous menu.
Set Step
You can select the search step for Custom Search.
Auto Automatically assign the search step based on the band.
5.0 kHz 15.0 kHz
6.25kHz 20.0 kHz
7.5 kHz 25.0 kHz
8.33kHz 50.0 kHz
10.0 kHz 100.0 kHz
12.5 kHz
Press [E / yes / gps] to accept the setting and return to the previous menu.