232
<COMMAND PRG>
Enter Program Mode
Controller Radio
PRG[\r]
Radio Controller
PRG,OK[\r]
PRG,NG[\r]
This command is invalid when the scanner is in Menu Mode, during Direct Entry
operation, during Quick Save operation.
The scanner goes to Program Mode.
The scanner displays "Remote Mode" on first line and "Keypad Lock" on second
line in Program Mode.
<COMMAND EPG>
Exit Program Mode
Controller Radio
EPG[\r]
Radio Controller
EPG,OK[\r]
The scanner exits from Program Mode.
Then the scanner goes to Scan Hold Mode.
<COMMAND BLT>
Get/Set Backlight
Controller Radio
BLT[\r]
BLT, [EVNT], [COLOR], [DIMMER] [\r]
Radio Controller
BLT, [EVNT], [COLOR], [DIMMER] [\r]
BLT,OK[\r]
[EVENT]
IF : INFINITE
10 : 10sec
30 : 30sec
KY : KEYPRESS
SQ : SQUELCH
[COLOR] : (BLUE,RED,MAGENTA,GREEN,CYAN,YELLOW,WHITE)
[DIMMER] : Backlight Dimmer (1:Low / 2:Middle / 3:High)
Get/Set Backlight Setting.
This command is only acceptable in Programming Mode.