260
<COMMAND SCN>
Get/Set Scanner Option Settings
Controller → Radio
SCN[\r]
SCN,[DISP_MODE],[RSV],[CH_LOG],[G_ATT],[RSV],[P25_LPF][RSV],[RSV],[RSV],
[RSV],[RSV], [RSV],[RSV],[RSV],[RSV],[RSV], [RSV],[RSV],[RSV],[RSV],[RSV][\r]
Radio → Controller
SCN,[DISP_MODE],[RSV],[CH_LOG],[G_ATT],[RSV],[P25_LPF],[RSV],[RSV],[RSV],
[RSV], [RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV][\r]
SCN,OK[\r]
[DISP_MODE] : DISPLAY MODE ( 1:MODE1 / 2:MODE2 / 3:MODE3 )
[CH_LOG] : Control Channel Logging ( 0:OFF / 1:ON / 2:Extend )
[G_ATT] : Global attenuator ( 0: OFF / 1: ON )
[P25_LPF] : P25 Low-Pass Filter (0: OFF / 1: ON)
[RSV] : Reserve Parameter * This is always only “,”.
Get/Set Scanner Option Settings
This command is only acceptable in Programming Mode.
<COMMAND VOL>
Get/Set Volume Level Settings
Controller → Radio
VOL[\r]
VOL,[LEVEL][\r]
Radio → Controller
VOL,[LEVEL][\r]
VOL,OK[\r]
[LEVEL] : Volume Level ( 0 - 15 )
<COMMAND SQL>
Get/Set Squelch Level Settings
Controller → Radio
SQL[\r]
SQL,[LEVEL][\r]
Radio → Controller
SQL,[LEVEL][\r]
SQL,OK[\r]
[LEVEL] : Squelch Level (0:OPEN / 1-14 / 15:CLOSE)
<COMMAND P25>
Get/Set APCO Data Settings
Controller → Radio
P25[\r]
Radio → Controller
P25,[RSV],[RSV],[ERR_RATE][\r]
[ERR_RATE] : Error Rate (from 0 to 99)